30 Washburn

Borrego Solar | 2.8 MW | June 2018

  • Share:

The project was a 2.8MW project built with TerraSmart’s Fixed Tilt racking in portrait orientation.

The site had many rocks and difficult subsurface conditions along with undulating terrain. By using TerraSmart, the client (Borrego) was able to minimize grading. The site was designed to 125MPH wind loads with a 30PSF snow load. The client used 7,794 JA Solar 360 Watt Solar Panels.

We supplied 1862 Ground Screws (2100MM) and performed rock drilling on the site to create pilot holes for the ground screws.

Information

  • DC System Size

    2.8 MW

  • Type of Rack

    Fixed-Tilt TF2 Portrait

  • Ground Screws

    1,862

  • TerraSmart Tables

    433

  • Modules

    7,794

  • Manufacturer

    JA Solar

Design Specification

  • Wind Load

    125 MPH

  • Snow Load

    30 PSF

  • Exposure Category

    C

  • Distance from Grade

    30 in

  • Soil Type

    Rock

  • Terrain

    Undulating